Display

Text size

Line spacing

Strengthens text and border colors for low-vision reading.

Overrides your system motion preference for this device.

Theme: mint-dark

Calculators/Acid-Base & Electrolytes/Serum Anion Gap & Albumin-Corrected Anion Gap
Acid-Base & ElectrolytesEvidence-Based Golden Standard

Serum Anion Gap & Albumin-Corrected Anion Gap

Calculates serum anion gap with Figge albumin correction to unmask occult high-anion-gap metabolic acidosis in hypoalbuminemia.

AG = Na⁺ - (Cl⁻ + HCO₃⁻) Corrected AG = AG + 2.5 × (4.0 - Albumin [g/dL])
Published Clinical Benchmark Cases

Clinical Parameters & Inputs

Unit: mEq/L
mEq/L
Unit: mEq/L
mEq/L
Unit: mEq/L
mEq/L
Unit: g/dL
g/dL

Normal: 4.0 g/dL (40 g/L). Hypoalbuminemia lowers the baseline normal AG by ~2.5 mEq/L per 1 g/dL drop.

Computed OutputNormal AG
12mEq/L
Diagnostic Interpretation

Normal Anion Gap (12 mEq/L). If metabolic acidosis is present, suspect Normal Anion Gap Metabolic Acidosis (NAGMA/hyperchloremic) such as diarrhea, renal tubular acidosis (RTA), ureteral diversion, or normal saline resuscitation.

Calculation Breakdown
Uncorrected Anion Gap
140 - (104 + 24) =12 mEq/L
Figge Albumin Correction
12 + 2.5 × (4.0 - 4) =12 mEq/L
Albumin dropped by 0 g/dL below reference normal of 4.0 g/dL.
Clinical Decision Pearls
  • Always evaluate serum albumin when interpreting anion gap. For every 1.0 g/dL decrease in serum albumin, expected "normal" anion gap decreases by 2.5 mEq/L.
  • A "normal" uncorrected AG of 11 in a critically ill patient with serum albumin 1.5 g/dL represents an occult HAGMA with corrected AG of 17.25 mEq/L.
  • If corrected AG is elevated, immediately proceed to calculate the Delta-Delta ratio to check for mixed metabolic disorders.
Limitations & Confounders
  • Severe hyperkalemia or profound hypercalcemia mildly blunts the anion gap.
  • Immunoassay interference (e.g. bromide or iodide measured as chloride) can create pseudonegative anion gap.
Evidence & Citations
  • Figge J, et al. Anion gap and hypoalbuminemia. Crit Care Med. 1998;26(11):1807-1810.
  • Kraut JA, Madias NE. Serum anion gap: its uses and limitations in clinical medicine. Clin J Am Soc Nephrol. 2007;2(1):162-174.
Educational Reference Only: ClinInterpret is not a certified diagnostic medical device. Consult local hospital protocols and senior clinicians for patient care.
ClinInterpret • Medical Investigations Interpretation Platform
Report an issueDeterministic Informatics Engine • Pure Client-Side Privacy